RISK OF BURSTING
IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE
MOTOR AND PRESSURE SWITCH TO SPARK.
IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO
CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE,
CAUSING FIRE OR EXPLOSION.
RESTRICTING ANY OF THE COMPRESSOR VENTILATION
OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD
CAUSE FIRE.
COMBUSTIBLE MATERIALS WHICH COME INTO CONTACT WITH
HOT ENGINE PARTS CAN BECOME IGNITED.
UNATTENDED OPERATION OF THIS PRODUCT COULD
RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE.
ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTILATED
AREA FREE OF COMBUSTIBLE MATERIALS, GASOLINE OR
SOLVENT VAPORS.
IF SPRAYING FLAMMABLE MATERIALS, LOCATE COMPRESSOR
AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN ADDITIONAL
LENGTH OF HOSE MAY BE REQUIRED.
STORE FLAMMABLE MATERIALS IN A SECURE LOCATION
AWAY FROM COMPRESSOR.
NEVER PLACE OBJECTS AGAINST OR ON TOP OF
COMPRESSOR. OPERATE COMPRESSOR IN AN OPEN AREA AT
LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION
THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE
VENTILATION OPENINGS.
ADD FUEL OUTDOORS IN A WELL VENTILATED AREA. MAKE
SURE THERE ARE NO SOURCES OF IGNITION, SUCH AS
CIGARETTES NEAR REFUELING LOCATION.
OPERATE COMPRESSOR IN A CLEAN, DRY, WELL VENTILATED
AREA A MINIMUM OF FOUR FEET FROM ANY BUILDING, OBJECT
OR WALL. DO NOT OPERATE UNIT INDOORS OR IN ANY CON-
FINED AREA.
ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT
WHEN IT IS OPERATING.
SAVE THESE INSTRUCTIONS
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAM-
AGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
RISK OF EXPLOSION OR FIRE
AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A
VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY.
DRAIN TANK DAILY OR AFTER EACH USE. IF TANK DEVELOPS A
LEAK, REPLACE IT IMMEDIATELY WITH A NEW TANK OR REPLACE
THE ENTIRE COMPESSOR.
NEVER DRILL INTO, WELD, OR MAKE ANY MODIFICATIONS TO
THE TANK OR ITS ATTACHMENTS.
THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING
PRESSURES. NEVER MAKE ADJUSTMENTS OR PARTS
SUBSTITUTIONS TO ALTER THE FACTORY SET OPERATING
PRESSURES.
DO NOT REMOVE THE STIFFENER BAR CONNECTING THE
COMPRESSOR PUMP TO THE ENGINE, EXCEPT TO ADJUST BELT
TENSION, THEN SECURELY TIGHTEN THE STIFFNER BAR NUTS.
THIS BAR CONTROLS OUTFIT VIBRATION.
FOR ESSENTIAL CONTROL OF AIR PRESSURE, YOU MUST INSTALL
A PRESSURE REGULATOR AND PRESSURE GAUGE TO THE AIR
OUTLET OF YOUR COMPRESSOR. FOLLOW THE EQUIPMENT
MANUFACTURERS RECOMMENDATION AND NEVER EXCEED THE
MAXIMUM ALLOWABLE PRESSURE RATING OF ATTACHMENTS.
NEVER USE COMPRESSOR TO INFLATE SMALL LOW-PRESSURE
OBJECTS SUCH AS CHILDREN’S TOYS, FOOTBALLS, BASKET-
BALLS. ETC.
1. FAILURE TO PROPERLY DRAIN CONDENSED WATER
FROM THE TANK, CAUSING RUST AND THINNING OF THE
STEEL TANK.
2. MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK.
3. UNAUTHORIZED MODIFICATIONS TO THE UNLOADER
VALVE, SAFETY VALVE, OR ANY OTHER COMPONENTS
WHICH CONTROL TANK PRESSURE.
4. EXCESSIVE VIBRATION CAN WEAKEN THE AIR TANK AND
CAUSE RUPTURE OR EXPLOSION. EXCESSIVE
VIBRATION WILL OCCUR IF THE COMPRESSOR IS NOT
PROPERLY MOUNTED OR IF THE ENGINE OPERATES
ABOVE RECOMMENDED RPM.
ATTACHMENTS & ACCESSORIES:
EXCEEDING THE PRESSURE RATING OF AIR TOOLS, SPRAY
GUNS, AIR OPERATED ACCESSORIES, TIRES AND OTHER
INFLATABLES CAN CAUSE THEM TO EXPLODE OR FLY APART,
AND COULD RESULT IN SERIOUS INJURY.
HAZARD
WHAT CAN HAPPEN
HOW TO PREVENT IT
WHAT CAN HAPPEN
HOW TO PREVENT IT
IMPORTANT SAFETY INSTRUCTIONS