STEEL DRIVER SERIES
Operation, Maintenance, and Parts Manual for SFN6
STICK FRAMING NAILER
Specifications
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615
MGP-SFN6-1 7/15/97
MODEL ........................................................... SFN6
AIR INLET........................................................ 1/4" NPT
WEIGHT .......................................................... 7 lbs. 6 ozs.
LENGTH .......................................................... 22.8"
HEIGHT ........................................................... 15.2"
MAXIMUM PRESSURE .................................. 125 PSI
PRESSURE RANGE......................................... 80-115 PSI
FASTENER LENGTHS .................................... 2" - 3 1/2"
MAGAZINE CAPACITY .................................. 75-105 Nails
SCFM REQUIRED @ 90 PSI ........................... Every 10 Fasteners
MINIMUM COMPRESSOR HP
REQUIRED TO OPERATE ............................... 3/4 HP
This manual contains information that is important for you to know and understand.
This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT
PROBLEMS. PLEASE READ THIS MANUAL.
Delivered Per Minute
Requires .95 SCFM
(TANK MOUNTED)
DeVILBISS AIR POWER COMPANY
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - DeVILBISS AIR POWER COMPANY

STEEL DRIVER SERIESOperation, Maintenance, and Parts Manual for SFN6STICK FRAMING NAILERSpecificationsDeVilbiss Air Power Company • 213 Industrial Dri

Page 2 - TABLE OF CONTENTS

10Disconnect tool from air supply before adjusting,clearing jams, servicing, relocating and during non-operation.LOADING THE TOOL1. Disconnect air s

Page 3 - LIMITED WARRANTY

111. Add a drop of DeVilbiss DV1719-01 Air Tool Oil, highspeed spindle oil, such as Unocal RX22, or 3-in1 oilinto the air inlet.2. Connect the Tool

Page 4 - Risk of explosion

12TROUBLESHOOTING GUIDESOLUTIONSeals must be replaced & operation ofContact trip must be checked. (NSK-017)Spring needs to be replaced. (NSK-009

Page 6 - Risk from flying objects

14PARTS LISTKEY PARTNO. NO. DESCRIPTION 1. NSP-185 SET SCREW2. NSP-186 DUST CAP3. NSP-187 HEX HEAD BOLT4. NSP-188 CYLINDER CAP* 5. ----- CAP SEAL6.

Page 7 - LUBRICATION AND MAINTENANCE

15FASTENERS 15Penny8d10d10d12d16d8d10d10d12d10dLength2 3/8"3"3"3 1/4"3 1/2"2 3/83"3"3 1/4"3ShankGauge.113"

Page 8

STEEL DRIVER SERIESOperating, Maintenance and PartsManual for SFN6Stick Framing NailerRetain the originalsales receipts asproof of purchase forwarrant

Page 9 - CONTACT TRIP SAFETY MECHANISM

2 PAGETool Specifications ... Front CoverTable of Contents

Page 10 - OPERATING THE TOOL

3LIMITED WARRANTYONE YEAR FROM DATE OF PURCHASEAll merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workm

Page 11

4SAFETY GUIDELINESIMPORTANT SAFETY INFORMATION A.HAZARD THAT MIGHT CAUSE SERIOUSINJURY OR LOSS OF LIFE.This manual contains information that is impor

Page 12 - TROUBLESHOOTING GUIDE

5SAFETY GUIDELINESRead these warnings carefully. Failure to followwarnings will result in severe injury or death!DANGERRisk of head injury.WHAT COULD

Page 13 - EXPLODED VIEW

6WHAT COULD HAPPENAccidental discharge of a fastener canoccur.HOW TO PREVENT ITHold tool by the handle and keep triggerand contact trip safety mechani

Page 14 - PART KITS

7Many air tool users find it convenient to use a Filter toremove liquid and solid impurities which can rust or"gum up" internal parts of th

Page 15 - INTERCHANGE INFORMATION

8Always connect the Female Quick Coupler to the air hose.Never connect the Female Quick Coupler to the tool.LUBRICATION AND MAINTENANCEThe air compr

Page 16

9Never keep the trigger pulled on contact trip toolswhen carrying or holding the tool. Death or a seriouspuncture wound could occur if the contact tri