Before Starting
Break-in instructions
Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor is put into service and
when the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Auto/Off lever is in the "OFF" position.
NOTE: If quick connect is installed, pull coupler back until it clicks to prevent
air from escaping through the quick connect.
2.
Plug the power cord into the correct branch circuit receptacle.
(Refer to
Voltage and Circuit Protection paragraph in the Installation section of this
manual.)
3. Open the drain valve fully to permit air to
escape and prevent air pressure build up in
the air tank during the break-in period.
NOTE: Always drain tank on a washable surface
or in a suitable container to prevent damaging or
staining surfaces.
4. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will
start.
5. Run the compressor for 15 minutes. Make sure the drain valve is open and
there is minimal air pressure build-up in tank.
6. After 15 minutes, close the drain valve. The
air receiver will fill to “cut-out” pressure and
the motor will stop.
The compressor is now ready for use.
Open Drain
Valve
Closed Drain
Valve
Open Drain
Valve
Closed Drain
Valve
Before Each Start-Up:
1. Place On/Auto/Off lever to "OFF".
2. Turn the regulator knob counter-clockwise to set the outlet pressure to
zero.
3. Attach hose and accessories. NOTE: The hose or accessory will require a
quick connect plug if the air outlet is equipped with a quick connect socket.
Risk of Bursting. Too much air pressure causes a hazardous
risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet pressure
must never exceed the maximum pressure rating.
How to Start:
1. Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2. Turn regulator knob clockwise to increase pressure and stop when desired
pressure is reached.
The compressor is ready for use.